{"product_id":"planet-igs-5225-8p2s2x-network-switch-managed-l3-gigabit-ethernet-101001000-power-over-ethernet-poe-blue-silver","title":"PLANET IGS-5225-8P2S2X network switch Managed L3 Gigabit Ethernet (10\/100\/1000) Power over Ethernet (PoE) Blue, Silver","description":"\u003cdiv id=\"icepim-bulletpoints\"\u003e\u003cul\u003e\n\u003cli\u003ePhysical Port\u003c\/li\u003e\n\u003cli\u003eEight 10\/100\/1000BASE-T Gigabit Ethernet RJ45 ports with IEEE 802.3at PoE+ Injector function\u003c\/li\u003e\n\u003cli\u003e2 100\/1000\/2500BASE-X mini-GBIC\/SFP slots for SFP type auto detection\u003c\/li\u003e\n\u003cli\u003e2 10GBASE-SR\/LR SFP+ slots, backward compatible with 1000BASE-SX\/LX\/BX and 2500BASE-X SFP\u003c\/li\u003e\n\u003cli\u003eOne RJ45 console interface for basic management and setup\u003c\/li\u003e\n\u003cli\u003ePower over Ethernet\u003c\/li\u003e\n\u003cli\u003eComplies with IEEE 802.3at Power over Ethernet Plus\/end-span PSE\u003c\/li\u003e\n\u003cli\u003eUp to 8 IEEE 802.3af\/802.3at devices powered\u003c\/li\u003e\n\u003cli\u003eSupports PoE power up to 36 watts for each PoE port\u003c\/li\u003e\n\u003cli\u003eAuto detects powered device (PD)\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports\u003c\/li\u003e\n\u003cli\u003eRemote power feeding up to 100m\u003c\/li\u003e\n\u003cli\u003ePoE management features\u003c\/li\u003e\n\u003cli\u003eTotal PoE power budget control\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE admin-mode control\u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limit\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\u003c\/li\u003e\n\u003cli\u003eTemperature threshold control\u003c\/li\u003e\n\u003cli\u003ePoE usage threshold control\u003c\/li\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003cli\u003eIndustrial Protocol\u003c\/li\u003e\n\u003cli\u003eModbus TCP for real-time monitoring in the SCADA system\u003c\/li\u003e\n\u003cli\u003eIEEE 1588v2 PTP (Precision Time Protocol)\u003c\/li\u003e\n\u003cli\u003eIndustrial Case and Installation\u003c\/li\u003e\n\u003cli\u003eIP30 aluminum case\u003c\/li\u003e\n\u003cli\u003eDIN-rail and wall-mount designs\u003c\/li\u003e\n\u003cli\u003e48~56V DC, redundant power with reverse polarity protection\u003c\/li\u003e\n\u003cli\u003eSupports 6000V DC Ethernet ESD protection\u003c\/li\u003e\n\u003cli\u003e40 to 75 degrees C operating temperature\u003c\/li\u003e\n\u003cli\u003eLayer 2 Features\u003c\/li\u003e\n\u003cli\u003ePrevents packet loss with back pressure (half-duplex) and IEEE 802.3x pause frame flow control (full-duplex)\u003c\/li\u003e\n\u003cli\u003eHigh performance of Store-and-Forward architecture, and runt\/CRC filtering that eliminates erroneous packets to optimize the network bandwidth\u003c\/li\u003e\n\u003cli\u003eStorm Control support\u003c\/li\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unicast\u003c\/li\u003e\n\u003cli\u003eSupports VLAN\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eUp to 4K VLANs groups, out of 4095 VLAN IDs\u003c\/li\u003e\n\u003cli\u003eProvider Bridging (VLAN Q-in-Q) support (IEEE 802.1ad)\u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP (GARP VLAN Registration Protocol)\u003c\/li\u003e\n\u003cli\u003eSupports Spanning Tree Protocol\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\u003c\/li\u003e\n\u003cli\u003eSupports Link Aggregation\u003c\/li\u003e\n\u003cli\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eMaximum 6 trunk groups with 4 ports per trunk group\u003c\/li\u003e\n\u003cli\u003eUp to 16Gbps bandwidth (duplex mode)\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (many-to-1)\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port\u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eSupports ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco Uni-directional link detection(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP)\u003c\/li\u003e\n\u003cli\u003eLayer 3 IP Routing Features\u003c\/li\u003e\n\u003cli\u003eSupports maximum 128 static routes and route summarization\u003c\/li\u003e\n\u003cli\u003eIPv4 dynamic routing protocol supports OSPFv2\u003c\/li\u003e\n\u003cli\u003eIPv4\/IPv6 hardware static routing\u003c\/li\u003e\n\u003cli\u003eRouting interface provides per VLAN routing mode\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-short-desc\"\u003eIndustrial L3 8-Port 10\/100\/1000T 802.3at PoE + 2-Port 1G\/2.5G SFP + 2-Port 10G SFP+ Managed Ethernet Switch\u003c\/div\u003e\u003cdiv id=\"icepim-long-desc\"\u003e\u003cp id=\"ice_long_description\"\u003eLayer 3 Capability and 10G Uplinks\u003cbr\u003e\u003cbr\u003ePLANET IGS-5225-8P2S2X is the smallest 10G uplink Layer 3 managed PoE switch preferably designed for industrial networks. Based on its 10Gbps big pipe connectivity to core networks, the IGS-5225-8P2S2X, equipped with 8 Gigabit ports featuring 36-watt 802.3at PoE+ and two 10Gbps SFP+ uplink slots, meets the demands of high power consumption and high bandwidth for 11ac Gigabit Wi-Fi APs and other PoE applications like those requiring heavy traffic loading. \u003cbr\u003e\u003cbr\u003eWith a rugged IP30 metal case and wide temperature range from -40 to 75 degrees C, the IGS-5225-8P2S2X is able to stably operate in heavy Industrial demanding environments. Thus, the IGS-5225-8P2S2X provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curbside traffic control cabinets. The IGS-5225-8P2S2X also allows either DIN-rail or wall mounting for efficient use of cabinet space.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003cbr\u003e\u003cbr\u003eThe IGS-5225-8P2S2X supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a ring network, the recovery time of data link can be as fast as 10ms.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eFlexible and Extendable 10Gb Ethernet Solution\u003cbr\u003e\u003cbr\u003e10G Ethernet is a big leap in the evolution of Ethernet. Each of the 10G SFP+ slots in the IGS-5225-8P2S2X supports triple speed and 10GBASE-SR\/LR, 2500BASE-X or 1000BASE-SX\/LX, providing broad bandwidth and powerful processing capacity. With its 2-port, 10G Ethernet link capability, the administrator now can flexibly choose the suitable SFP\/SFP+ transceiver according to the transmission distance or the transmission speed required to extend the network efficiently. \u003cbr\u003e\u003cbr\u003e \u003cbr\u003eIntelligent LED Indicator for Real-time PoE Usage\u003cbr\u003e\u003cbr\u003eThe IGS-5225-8P2S2X helps users to monitor current status of PoE power usage easily and efficiently by its advanced LED indication. The front panel of the Industrial Gigabit PoE+ Switch has four orange LEDs indicating 60W, 120W, 180W and 240W of PoE power usage.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eIntelligent Alive Check for Powered Device\u003cbr\u003e\u003cbr\u003eThe IGS-5225-8P2S2X PoE Switch can be configured to monitor connected PD’s status in real time via ping action. Once the PD stops working and responding, the IGS-5225-8P2S2X will recycle the PoE port power and bring the PD back to work. It also greatly enhances the reliability in that the PoE port will reset the PD power, thus reducing administrator’s management burden.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003ePoE Schedule for Energy Saving\u003cbr\u003e\u003cbr\u003eUnder the trend of energy saving worldwide and contributing to environmental protection on the Earth, the IGS-5225-8P2S2X can effectively control the power supply besides its capability of giving high watts power. The built-in “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eScheduled Power Recycling\u003cbr\u003e\u003cbr\u003eThe IGS-5225-8P2S2X allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eConvenient and Smart ONVIF Devices with Detection Feature\u003cbr\u003e\u003cbr\u003ePLANET has newly developed an awesome feature -- ONVIF Support -- which is specifically designed for cooperating with video IP surveillances. From the IGS-5225-8P2S2X GUI, you just need one click to search and show all of the ONVIF devices via network application. In addition, you can upload floor images to the switch and remotely monitor what is going on in the production line. Moreover, you can get real-time surveillance’s information and online\/offline status, and can have PoE reboot control from GUI.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e1588 Time Protocol for Industrial Computing Networks\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eLayer 3 IPv4 and IPv6 Software VLAN Routing for Secure and Flexible Management\u003cbr\u003e\u003cbr\u003eTo help customers stay on top of their businesses, the IGS-5225 series not only provides ultra high transmission performance and excellent Layer 2 technologies, but also IPv4\/IPv6 software VLAN routing feature which allows to crossover different VLANs and different IP addresses for the purpose of having a highly-secure, flexible management and simpler networking application.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eCybersecurity Network Solution to Minimize Security Risks\u003cbr\u003e\u003cbr\u003eThe new generation of IGS-5225 series has the cybersecurity feature to protect the switch management and enhance the security for mission-critical network without extra deployment cost and effort. The IGS-5225 series expands its memory and upgrades the kernel of SSH, TLS and SSL protocols to provide strong protection against advanced threats. It includes a range of cybersecurity features such as DHCP Snooping, IP Source Guard, ARP Inspection Protection, 802.1x port-based and Mac-based network access control, RADIUS and TACACS+ user accounts management, SNMPv3 authentication, and so on to complement it as an all-security solution. The network administrator can now construct highly-secure corporate networks with considerably less time and effort than before.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eEffective Alarm Alert for Better Protection\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eSMTP\/SNMP Trap Event Alert\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eDigital Input and Digital Output for External Alarm\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series supports Digital Input and Digital Output on its front panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to alarm the administrators if the IGS-5225 series port shows link down, link up or power failure.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eRobust Layer 2 to Layer 4 Features\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series can be programmed for advanced switch management functions such as dynamic port link aggregation, Q-in-Q VLAN, private VLAN, Rapid Spanning Tree Protocol, Layer 2 to Layer 4 QoS, bandwidth control and IGMP snooping. The IGS-5225 series provides 802.1Q tagged VLAN, and the VLAN groups allowed will be maximally up to 4000. Via aggregation of supporting ports, the IGS-5225-8P2S2X allows the operation of a high-speed trunk combining multiple ports. It enables a maximum of up to 6 trunk groups with 4 ports per trunk group, and supports fail-over as well. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eEfficient Management\u003cbr\u003e\u003cbr\u003eFor efficient management, the IGS-5225 Managed Ethernet Switch series is equipped with console, Web and SNMP management interfaces. With the built-in Web-based management interface, the IGS-5225 series offers an easy-to-use, platform-independent management and configuration facility. For text-based management, the IGS-5225 series can be accessed via Telnet and the console port. Moreover, it also offers secure remote management via any standard-based management software by supporting SNMP v3 connection which encrypts the packet content at each session.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003ePowerful Security\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series offers comprehensive Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1x Port-based and MAC-based user and device authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003cbr\u003e\u003cbr\u003e \u003cbr\u003eFlexibility and Extension Solution\u003cbr\u003e\u003cbr\u003eThe additional two mini-GBIC slots built in the IGS-5225-8P2S2X support triple-speed 100\/1000\/2500BASE-X SFP (small form-factor pluggable) fiber-optic modules, meaning the administrator now can flexibly choose the suitable SFP transceiver according to not only the transmission distance but also the transmission speed required. The distance can be extended from 300 meters to 2 kilometers (multi-mode fiber) and 10\/20\/40\/60\/80\/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications to uplink to backbone switch and monitoring center in long distance.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eIntelligent SFP Diagnosis Mechanism\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series supports SFP-DDM (Digital Diagnostic Monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eModbus TCP provides Flexible Network Connectivity for Factory Automation\u003cbr\u003e\u003cbr\u003eWith the supported Modbus TCP\/IP protocol; the IGS-5225 series can easily integrate with SCADA systems, HMI systems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s operating information, port information and communication status, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-attributes\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eManagement features\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch type\u003c\/td\u003e\n\u003ctd\u003eManaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch layer\u003c\/td\u003e\n\u003ctd\u003eL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality of Service (QoS) support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb-based management\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP inspection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports quantity\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports type\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP module slots quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ module slots quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber optic connector\u003c\/td\u003e\n\u003ctd\u003eSFP, SFP+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eNetwork\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworking standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1ab, IEEE 802.1ad, IEEE 802.1ag, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3af, IEEE 802.3ah, IEEE 802.3at, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10G support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper ethernet cabling technology\u003c\/td\u003e\n\u003ctd\u003e10BASE-T, 100BASE-TX, 1000BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort mirroring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP routing\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull duplex\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting entries\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC address auto-aging supported\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC address auto-learning supported\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink aggregation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-negotiation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow control support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtual LAN features\u003c\/td\u003e\n\u003ctd\u003ePrivate VLAN, Tagged VLAN, Protocol-based VLAN, MAC address-based VLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of VLANs\u003c\/td\u003e\n\u003ctd\u003e4094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOptical fiber\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eFiber ethernet cabling technology\u003c\/td\u003e\n\u003ctd\u003e10GBASE-LR, 10GBASE-SR, 1000BASE‑BX, 1000BASE‑LX, 1000BASE‑SX\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eData transmission\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC address table\u003c\/td\u003e\n\u003ctd\u003e32000 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd\u003e66 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput\u003c\/td\u003e\n\u003ctd\u003e49.107 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStore-and-forward\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of queues\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic route\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of static routes\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames\u003c\/td\u003e\n\u003ctd\u003e10000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket buffer memory\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eSecurity\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDHCP features\u003c\/td\u003e\n\u003ctd\u003eDHCP snooping, DHCP relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Control List (ACL)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Control List (ACL) rules\u003c\/td\u003e\n\u003ctd\u003e123\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGMP snooping\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication\u003c\/td\u003e\n\u003ctd\u003eMAC-based authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSH\/SSL support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication type\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x, RADIUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity algorithms\u003c\/td\u003e\n\u003ctd\u003eSNMP, SNMPv3, SSH, SSL\/TLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eMulticast features\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eMulticast support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlue, Silver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eAluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset button\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eLAN, PoE, System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Protection (IP) code\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall mountable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eFCC 15 A, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input voltage\u003c\/td\u003e\n\u003ctd\u003e48 - 56 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (max)\u003c\/td\u003e\n\u003ctd\u003e306 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePower over Ethernet (PoE)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet plus (PoE+) ports quantity\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet (PoE) power per port\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power over Ethernet (PoE) budget\u003c\/td\u003e\n\u003ctd\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1043.46 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e72 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eLogistics data\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85176990\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv id=\"icepim-pdf-urls\"\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.iceshop.nl\/objects\/mmo_39923462_1512647889_5635_6052.pdf\" target=\"_blank\"\u003eleaflet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.iceshop.nl\/objects\/mmo_39923462_1512647988_655_21900.pdf\" target=\"_blank\"\u003emanual pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":55913297936769,"sku":"IGS-5225-8P2S2X","price":504.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/7725\/7955\/files\/e8c23c1432d82ad03e665f3297de0ccc.jpg?v=1784014717","url":"https:\/\/eurobusinessproducts.co.uk\/products\/planet-igs-5225-8p2s2x-network-switch-managed-l3-gigabit-ethernet-101001000-power-over-ethernet-poe-blue-silver","provider":"EuroBusiness Products UK","version":"1.0","type":"link"}