{"product_id":"planet-igs-5225-4up1t2s-network-switch-managed-l2-gigabit-ethernet-101001000-power-over-ethernet-poe-blue-silver","title":"PLANET IGS-5225-4UP1T2S network switch Managed L2+ Gigabit Ethernet (10\/100\/1000) Power over Ethernet (PoE) Blue, Silver","description":"\u003cdiv id=\"icepim-bulletpoints\"\u003e\u003cul\u003e\n\u003cli\u003ePhysical Port\u003c\/li\u003e\n\u003cli\u003e4 10\/100\/1000BASE-T Gigabit Ethernet RJ45 ports with 802.3bt PoE++ Injector function\u003c\/li\u003e\n\u003cli\u003e1 10\/100\/1000BASE-T Gigabit Ethernet RJ45 port\u003c\/li\u003e\n\u003cli\u003e2 100\/1000BASE-X mini-GBIC\/SFP slots for SFP type auto detection\u003c\/li\u003e\n\u003cli\u003eOne RJ45 console interface for basic management and setup\u003c\/li\u003e\n\u003cli\u003e802.3bt Power over Ethernet\u003c\/li\u003e\n\u003cli\u003eComplies with IEEE 802.3bt Power over Ethernet Plus Plus Type-4 PSE\u003c\/li\u003e\n\u003cli\u003eBackward compatible with IEEE 802.3at\/af PD device\u003c\/li\u003e\n\u003cli\u003eUp to 4 ports of IEEE 802.3af\/IEEE 802.3at\/IEEE 802.3bt PoE++ devices powered\u003c\/li\u003e\n\u003cli\u003eSupports PoE power up to 95 watts for each PoE port\u003c\/li\u003e\n\u003cli\u003eTotal of 240-watt PoE budget\u003c\/li\u003e\n\u003cli\u003eAuto detects powered device (PD)\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports\u003c\/li\u003e\n\u003cli\u003eRemote power feeding up to 100m\u003c\/li\u003e\n\u003cli\u003ePoE management features\u003c\/li\u003e\n\u003cli\u003eTotal PoE power budget control\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE admin-mode control\u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limit\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\u003c\/li\u003e\n\u003cli\u003eTemperature threshold control\u003c\/li\u003e\n\u003cli\u003ePoE usage threshold control\u003c\/li\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003cli\u003eIndustrial Case and Installation\u003c\/li\u003e\n\u003cli\u003eIP30 aluminum case\u003c\/li\u003e\n\u003cli\u003eDIN-rail or wall-mount design\u003c\/li\u003e\n\u003cli\u003e48~56V DC, redundant power with reverse polarity protection\u003c\/li\u003e\n\u003cli\u003eSupports 6000V DC Ethernet ESD protection\u003c\/li\u003e\n\u003cli\u003eSupports -40 to 75 degrees C operating temperature\u003c\/li\u003e\n\u003cli\u003eDigital Input and Digital Output\u003c\/li\u003e\n\u003cli\u003e2 Digital Input (DI)\u003c\/li\u003e\n\u003cli\u003e2 Digital Output (DO)\u003c\/li\u003e\n\u003cli\u003eIntegrate sensors into auto alarm system\u003c\/li\u003e\n\u003cli\u003eTransfer alarm to IP network via email and SNMP trap\u003c\/li\u003e\n\u003cli\u003eLayer 2 Features\u003c\/li\u003e\n\u003cli\u003eHigh performance of Store-and-Forward architecture, and runt\/CRC filtering eliminates erroneous packets to optimize the network bandwidth\u003c\/li\u003e\n\u003cli\u003eStorm Control support\u003c\/li\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unicast\u003c\/li\u003e\n\u003cli\u003eSupports VLAN\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eUp to 255 VLANs groups, out of 4095 VLAN IDs\u003c\/li\u003e\n\u003cli\u003eSupports provider bridging (VLAN Q-in-Q IEEE 802.1ad)\u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP (GARP VLAN Registration Protocol)\u003c\/li\u003e\n\u003cli\u003eSupports Spanning Tree Protocol\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\u003c\/li\u003e\n\u003cli\u003eSupports Link Aggregation\u003c\/li\u003e\n\u003cli\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eMaximum 3 trunk groups with 3 ports per trunk group\u003c\/li\u003e\n\u003cli\u003eUp to 6Gbps bandwidth (duplex mode)\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (1-to-1)\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port\u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eSupports G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco uni-directional link detection(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP)\u003c\/li\u003e\n\u003cli\u003eLayer 3 IP Routing Features\u003c\/li\u003e\n\u003cli\u003eIPv4\/IPv6 Layer 3 static routing\u003c\/li\u003e\n\u003cli\u003eSupports maximum 32 software static routes and route summarization\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-short-desc\"\u003eIndustrial L2+ 4-Port 10\/100\/1000T 802.3bt PoE + 1-Port 10\/100\/1000T + 2-Port 100\/1000X SFP Managed Switch\u003c\/div\u003e\u003cdiv id=\"icepim-long-desc\"\u003e\u003cp id=\"ice_long_description\"\u003eOutstanding 802.3bt PoE++ Solution for Hardened Environment\u003cbr\u003e\u003cbr\u003eComplying with the IEEE 802.3bt Power over Ethernet Plus Plus technology, the latest version of PLANET IGS-5225-4UP1T2S L2+ Industrial Managed PoE++ Switch features four 10\/100\/1000BASE-T 802.3bt PoE++ ports with each port powering up to 95 watts, one extra 10\/100\/1000BASE-T copper port and two 100\/1000BASE-X SFP interfaces in a rugged IP30 metal case for stable operation in heavy industrial demanding environments. It supports rich PoE operation modes including 90-watt 802.3bt type-4 PoE++ ports, 95-watt PoH (Power over HD-BASE-T) mode and 4-pair force mode to solve the incompatibility of non-standard 4-pair PoE PDs in the field. \u003cbr\u003e\u003cbr\u003eBeing able to operate under wide temperature range from -40 to 75 degrees C, the IGS-5225-4UP1T2S can be placed in almost any difficult environment. The IGS-5225-4UP1T2S also allows either DIN rail or wall mounting for efficient use of cabinet space.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e802.3bt PoE++ – 90~95-watt Power over 4-pair UTP Solution\u003cbr\u003e\u003cbr\u003eAs the IGS-5225-4UP1T2S adopts the IEEE 802.bt PoE++ standard and PoH technology, it is capable to source up to 95 watts of power by using all the four pairs of standard Cat5e\/6 Ethernet cabling to deliver power and full-speed data to each remote PoE compliant powered device (PD). It possesses triple amount of power capability than the conventional 802.3at PoE+ and is an ideal solution to satisfy the growing demand for higher power consuming network PDs, such as:\u003cbr\u003e\u003cbr\u003e- PoE PTZ speed dome cameras\u003cbr\u003e- Network devices \u003cbr\u003e- Thin clients\u003cbr\u003e- AIO (all-in-one) touch PCs, point of sale (POS) and information kiosks\u003cbr\u003e- Remote digital signage displays\u003cbr\u003e- PoE lightings\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eAdvanced PoE Power Output Mode Management\u003cbr\u003e\u003cbr\u003eTo meet the demand of various powered devices consuming stable PoE power, the IGS-5225-4UP1T2S provides five different PoE power output modes for selection.\u003cbr\u003e\u003cbr\u003e- 90W 802.3bt PoE++ Power Output Mode(Pins 1, 2, 3, 6 + Pins 4, 5, 7, 8)\u003cbr\u003e- 95W UPOE\/PoH Power Output Mode(Pins 1, 2, 3, 6 + Pins 4, 5, 7, 8)\u003cbr\u003e- 30W End-span PoE Power Output Mode(Pins 1, 2, 3, 6)\u003cbr\u003e- 30W Mid-span PoE Power Output Mode(Pins 4, 5, 7, 8)\u003cbr\u003e- 60W Force Power Output Mode\u003cbr\u003e \u003cbr\u003e\u003cbr\u003eIntelligent Alive Check for Powered Device\u003cbr\u003e\u003cbr\u003eThe IGS-5225-4UP1T2S PoE Switch can be configured to monitor connected PD’s status in real time via ping action. Once the PD stops working and responding, the IGS-5225-4UP1T2S will recycle the PoE port power and bring the PD back to work. It also greatly enhances the reliability in that the PoE port will reset the PD power, thus reducing administrator’s management burden.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003ePoE Schedule for Energy Saving\u003cbr\u003e\u003cbr\u003eUnder the trend of energy saving worldwide and contributing to environmental protection on the Earth, the IGS-5225-4UP1T2S can effectively control the power supply besides its capability of giving high watts power. The built-in “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eScheduled Power Recycling\u003cbr\u003e\u003cbr\u003eThe IGS-5225-4UP1T2S allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003cbr\u003e\u003cbr\u003eThe IGS-5225-4UP1T2S supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a certain simple Ring network, the recovery time of data link can be as fast as 10ms.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eNetwork with Cybersecurity Helps Minimize Security Risks\u003cbr\u003e\u003cbr\u003eThe IGS-5225-4UP1T2S comes with enhanced cybersecurity to fend off cyberthreats and cyberattacks. Served as a key point to transmit data and offering over 95-watt PoE output to customer's critical equipment in a business network, the cybersecurity feature of the IGS-5225-4UP1T2S protects the switch management and enhances the security of the mission-critical network without any extra deployment cost and effort.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eConvenient and Smart ONVIF Devices with Detection Feature\u003cbr\u003e\u003cbr\u003ePLANET has newly developed an awesome feature -- ONVIF Support -- which is specifically designed for co-operating with video IP surveillances. From the IGS-5225-4UP1T2S GUI, clients just need one click to search and show all of the ONVIF devices via network application. In addition, clients can upload floor images to the switch, allowing to locate surveillance devices for easier inspection and planning. Moreover, clients can get real-time surveillance’s information and online\/offline status, and also allows PoE reboot control from GUI.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eSMTP\/SNMP Trap Event Alert\u003cbr\u003e\u003cbr\u003eThe IGS-5225-4UP1T2S provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eEffective Alarm Alert for Better Protection\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eDigital Input and Digital Output for External Alarm\u003cbr\u003e\u003cbr\u003eThe IGS-5225-4UP1T2S supports Digital Input and Digital Output on its front panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to alarm the administrators if the IGS-5225-4UP1T2S port shows link down, link up or power failure.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eLayer 3 IPv4 and IPv6 Software VLAN Routing for Secure and Flexible Management\u003cbr\u003e\u003cbr\u003eTo help customers stay on top of their businesses, the IGS-5225 series not only provides ultra high transmission performance and excellent Layer 2 technologies, but also IPv4\/IPv6 software VLAN routing feature which allows to cross over different VLANs and different IP addresses for the purpose of having a highly-secure, flexible management and simpler networking application.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eRobust Layer 2 Features\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series can be programmed for advanced switch management functions such as dynamic port link aggregation, Q-in-Q VLAN, private VLAN, Rapid Spanning Tree Protocol, Layer 2 to Layer 4 QoS, bandwidth control and IGMP snooping. The IGS-5225 series provides 802.1Q tagged VLAN, and the VLAN groups that can be maximized to 255. Via the aggregation of supporting ports, the IGS-5225-4UP1T2S allows the operation of a high-speed trunk group that comes with multiple ports. For example, it enables a maximum of up to 3 trunk groups with 3 ports per trunk group, and supports fail-over as well. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eEfficient Management\u003cbr\u003e\u003cbr\u003eFor efficient management, the IGS-5225 Managed Ethernet Switch series is equipped with console, Web and SNMP management interfaces. With the built-in Web-based management interface, the IGS-5225 series offers an easy-to-use, platform-independent management and configuration facility. For text-based management, the IGS-5225 series can be accessed via Telnet and the console port. Moreover, it also offers secure remote management via any standard-based management software by supporting SNMPv3 connection which encrypts the packet content at each session.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003ePowerful Security\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series offers comprehensive Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1X Port-based and MAC-based user and device authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eFlexibility and Extension Solution\u003cbr\u003e\u003cbr\u003eThe additional two mini-GBIC slots built in the IGS-5225-4UP1T2S support dual speed, 100BASE-FX and 1000BASE-SX\/LX SFP (small form-factor pluggable) fiber-optic modules, meaning the administrator now can flexibly choose the suitable SFP transceiver according to not only the transmission distance but also the transmission speed required. The distance can be extended from 550 meters (multi-mode fiber) to 10\/50\/70\/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eIntelligent SFP Diagnosis Mechanism\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series supports SFP-DDM (digital diagnostic monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e1588 Time Protocol for Industrial Computing Networks\u003cbr\u003e\u003cbr\u003eThe IGS-5225 series is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003cbr\u003e\u003cbr\u003eWith the supported Modbus TCP\/IP protocol, the IGS-5225-4UP1T2S can easily integrate with SCADA systems, HMI systems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s operating information, port information and communication status, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-attributes\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eManagement features\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb-based management\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality of Service (QoS) support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch layer\u003c\/td\u003e\n\u003ctd\u003eL2+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch type\u003c\/td\u003e\n\u003ctd\u003eManaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber optic connector\u003c\/td\u003e\n\u003ctd\u003eSFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP module slots quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports type\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports quantity\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eNetwork\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of VLANs\u003c\/td\u003e\n\u003ctd\u003e4095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtual LAN features\u003c\/td\u003e\n\u003ctd\u003ePrivate VLAN, Tagged VLAN, Protocol-based VLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow control support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-negotiation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink aggregation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpanning tree protocol\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting entries\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP routing\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull duplex\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort mirroring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper ethernet cabling technology\u003c\/td\u003e\n\u003ctd\u003e10BASE-T, 100BASE-TX, 1000BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10G support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworking standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D, IEEE 802.1Q, IEEE 802.1ab, IEEE 802.1ag, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3af, IEEE 802.3ah, IEEE 802.3at, IEEE 802.3bt, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOptical fiber\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eFiber ethernet cabling technology\u003c\/td\u003e\n\u003ctd\u003e1000BASE-FX, 1000BASE‑BX, 1000BASE‑LX\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eData transmission\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket buffer memory\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames\u003c\/td\u003e\n\u003ctd\u003e9000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of static routes\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic route\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of queues\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStore-and-forward\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput\u003c\/td\u003e\n\u003ctd\u003e10.42 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd\u003e14 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC address table\u003c\/td\u003e\n\u003ctd\u003e8000 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eSecurity\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication\u003c\/td\u003e\n\u003ctd\u003ePort-based authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity algorithms\u003c\/td\u003e\n\u003ctd\u003e802.1x RADIUS, SNMP, SNMPv3, SSH, SSL\/TLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication type\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x, RADIUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGMP snooping\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Control List (ACL) rules\u003c\/td\u003e\n\u003ctd\u003e123\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Control List (ACL)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDHCP features\u003c\/td\u003e\n\u003ctd\u003eDHCP snooping, DHCP relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eMulticast features\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eMulticast support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, CEIEC60068-2-32 (free fall)IEC60068-2-27 (shock)IEC60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall mountable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Protection (IP) code\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eLAN, PoE, System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset button\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eAluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlue, Silver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eFirmware upgradeable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input voltage\u003c\/td\u003e\n\u003ctd\u003e48 - 56 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePower over Ethernet (PoE)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power over Ethernet (PoE) budget\u003c\/td\u003e\n\u003ctd\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet (PoE) power per port\u003c\/td\u003e\n\u003ctd\u003e72 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet plus (PoE+) ports quantity\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e962.22 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e107.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e76.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eLogistics data\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85176990\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOther features\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eTerminal block port\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv id=\"icepim-pdf-urls\"\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.iceshop.nl\/objects\/mmo_39923468_1512646777_3724_1141.pdf\" target=\"_blank\"\u003eleaflet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.iceshop.nl\/objects\/mmo_39923468_1512646906_7697_7132.pdf\" target=\"_blank\"\u003emanual pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":55046346473857,"sku":"IGS-5225-4UP1T2S","price":429.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/7725\/7955\/files\/df914b8f8472f35d22a8301db6553679.jpg?v=1764837216","url":"https:\/\/eurobusinessproducts.co.uk\/products\/planet-igs-5225-4up1t2s-network-switch-managed-l2-gigabit-ethernet-101001000-power-over-ethernet-poe-blue-silver","provider":"EuroBusiness Products UK","version":"1.0","type":"link"}