{"product_id":"planet-igs-5225-4p2s-network-switch-managed-l2-gigabit-ethernet-101001000-power-over-ethernet-poe-blue","title":"PLANET IGS-5225-4P2S network switch Managed L2+ Gigabit Ethernet (10\/100\/1000) Power over Ethernet (PoE) Blue","description":"\u003cdiv id=\"icepim-bulletpoints\"\u003e\u003cul\u003e\n\u003cli\u003ePhysical Port\u003c\/li\u003e\n\u003cli\u003e4 10\/100\/1000BASE-T Gigabit Ethernet RJ45 ports with IEEE 802.3at PoE+ Injector\u003c\/li\u003e\n\u003cli\u003e2 100\/1000BASE-X mini-GBIC\/SFP slots for SFP type auto detection\u003c\/li\u003e\n\u003cli\u003eOne RJ45 console interface for basic management and setup\u003c\/li\u003e\n\u003cli\u003ePower over Ethernet\u003c\/li\u003e\n\u003cli\u003eComplies with IEEE 802.3at Power over Ethernet Plus\/end-span PSE\u003c\/li\u003e\n\u003cli\u003eUp to 4 IEEE 802.3af\/802.3at devices powered\u003c\/li\u003e\n\u003cli\u003eSupports PoE power up to 36 watts for each PoE port\u003c\/li\u003e\n\u003cli\u003eAuto detects powered device (PD)\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports\u003c\/li\u003e\n\u003cli\u003eRemote power feeding up to 100m\u003c\/li\u003e\n\u003cli\u003ePoE management features\u003c\/li\u003e\n\u003cli\u003eTotal PoE power budget control\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE admin-mode control\u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limit\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\u003c\/li\u003e\n\u003cli\u003eTemperature threshold control\u003c\/li\u003e\n\u003cli\u003ePoE usage threshold control\u003c\/li\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003cli\u003eIndustrial Protocol\u003c\/li\u003e\n\u003cli\u003eModbus TCP for real-time monitoring in a SCADA system\u003c\/li\u003e\n\u003cli\u003eIEEE 1588v2 PTP (Precision Time Protocol)\u003c\/li\u003e\n\u003cli\u003eIndustrial Case and Installation\u003c\/li\u003e\n\u003cli\u003eIP40 metal case\u003c\/li\u003e\n\u003cli\u003eDIN-rail and wall-mount designs\u003c\/li\u003e\n\u003cli\u003e48~56V DC, redundant power with polarity reverse protect function\u003c\/li\u003e\n\u003cli\u003eSupports 6000V DC Ethernet ESD protection\u003c\/li\u003e\n\u003cli\u003eSupports -40 to 75 degrees C operating temperature\u003c\/li\u003e\n\u003cli\u003eLayer 2 Features\u003c\/li\u003e\n\u003cli\u003eHigh performance of Store-and-Forward architecture, and runt\/CRC filtering eliminates erroneous packets to optimize the network bandwidth\u003c\/li\u003e\n\u003cli\u003eStorm Control support\u003c\/li\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unicast\u003c\/li\u003e\n\u003cli\u003eSupports VLAN\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eUp to 255 VLANs groups, out of 4094 VLAN IDs\u003c\/li\u003e\n\u003cli\u003eProvider Bridging (VLAN Q-in-Q) support (IEEE 802.1ad)\u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP (GARP VLAN Registration Protocol)\u003c\/li\u003e\n\u003cli\u003eSupports Spanning Tree Protocol\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\u003c\/li\u003e\n\u003cli\u003eSupports Link Aggregation\u003c\/li\u003e\n\u003cli\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eMaximum 2 trunk groups with 2 ports per trunk group\u003c\/li\u003e\n\u003cli\u003eUp to 4Gbps bandwidth (duplex mode)\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (many-to-1)\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port\u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eSupports ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco Uni-directional link detection(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP)\u003c\/li\u003e\n\u003cli\u003eLayer 3 IP Routing Features\u003c\/li\u003e\n\u003cli\u003eSupports maximum 32 static routes and route summarization\u003c\/li\u003e\n\u003cli\u003eQuality of Service\u003c\/li\u003e\n\u003cli\u003eIngress Shaper and Egress Rate Limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003e8 priority queues on all switch ports\u003c\/li\u003e\n\u003cli\u003eTraffic classification\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eIP TOS\/DSCP\/IP precedence\u003c\/li\u003e\n\u003cli\u003eIP TCP\/UDP port number\u003c\/li\u003e\n\u003cli\u003eTypical network application\u003c\/li\u003e\n\u003cli\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/li\u003e\n\u003cli\u003eSupports QoS and In\/Out bandwidth control on each port\u003c\/li\u003e\n\u003cli\u003eTraffic policing on the switch port\u003c\/li\u003e\n\u003cli\u003eDSCP remarking\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-short-desc\"\u003eL2+ Industrial 4-Port 10\/100\/1000T 802.3at PoE + 2-Port 100\/1000X SFP Managed Ethernet Switch\u003c\/div\u003e\u003cdiv id=\"icepim-long-desc\"\u003e\u003cp id=\"ice_long_description\"\u003e\u003cb\u003eAdvanced Manageable PoE Solution for Hardened Environment\u003c\/b\u003e\u003cbr\u003ePLANET IGS-5225-4P2S L2+ Industrial Managed PoE+ Switch, featuring 4 10\/100\/1000BASE-T 802.3at PoE+ ports with each port powering up to 36 watts, and 2 100\/1000X fiber ports in an IP40 rugged but compact-sized case, can be installed in any difficult environment without space limitation. It provides user-friendly yet advanced IPv6\/IPv4 management interfaces, abundant L2\/L4 switching functions, Layer 3 static routing capability, and advanced ITU-G.8032 ERPS Ring technology to improve the rapid self-recovery capability and PLANET intelligent PoE functions for controlling the PoE outdoor IP surveillance and wireless network applications. It is able to operate reliably, stably and quietly in the temperature range from -40 to 75 degrees C.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/b\u003e\u003cbr\u003eThe IGS-5225-4P2S supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a simple Ring network, the recovery time of data link can be as fast as 10ms.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCybersecurity Network Solution to Minimize Security Risks\u003c\/b\u003e\u003cbr\u003eThe cybersecurity feature that virtually needs no effort and cost to have includes the protection of the switch management and the enhanced security of the mission-critical network. Both SSH and SSL protocols are utilized to provide strong protection against advanced threats. The network administrator can now construct highly-secure corporate networks with considerably less time and effort than before.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eConvenient and Smart ONVIF Devices with Detection Feature\u003c\/b\u003e\u003cbr\u003ePLANET has newly developed an awesome feature -- ONVIF Support -- which is specifically designed for co-operating with video IP surveillances. From the IGS-5225-4P2S’ GUI, you just need one click to search and show all of the ONVIF devices via network application. In addition, you can upload floor images to the switch and can remotely monitor or inspect an assembly line. Moreover, you can get real-time surveillance information and online\/offline status; the PoE reboot can be controlled from the GUI.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBuilt-in Unique PoE Functions for Powered Devices Management\u003c\/b\u003e\u003cbr\u003eAs it is the managed PoE switch for surveillance, wireless and VoIP networks, the IGS-5225-4P2S features the following special PoE management functions:\u003cbr\u003e- PD alive check\u003cbr\u003e- Scheduled power recycling\u003cbr\u003e- PoE schedule\u003cbr\u003e- PoE usage monitoring\u003cbr\u003e\u003cbr\u003e\u003cb\u003eIntelligent Alive Check for Powered Device\u003c\/b\u003e\u003cbr\u003eThe IGS-5225-4P2S PoE Switch can be configured to monitor connected PD’s status in real time via ping action. Once the PD stops working and responding, the IGS-5225-4P2S will recycle the PoE port power and bring the PD back to work. It also greatly enhances the reliability in that the PoE port will reset the PD power, thus reducing administrator’s management burden.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePoE Schedule for Energy Saving\u003c\/b\u003e\u003cbr\u003eUnder the trend of energy saving worldwide and contributing to environmental protection on the Earth, the IGS-5225-4P2S can effectively control the power supply besides its capability of giving high watts power. The built-in “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eScheduled Power Recycling\u003c\/b\u003e\u003cbr\u003eThe IGS-5225-4P2S allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSMTP\/SNMP Trap Event Alert\u003c\/b\u003e\u003cbr\u003eThe IGS-5225-4P2S provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eEffective Alarm Alert for Better Protection\u003c\/b\u003e\u003cbr\u003eThe IGS-5225-4P2S supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eLayer 3 IPv4 and IPv6 Software VLAN Routing for Secure and Flexible Management\u003c\/b\u003e\u003cbr\u003eTo help customers stay on top of their businesses, the IGS-5225-4P2S not only provides ultra high transmission performance and excellent Layer 2 technologies, but also IPv4\/IPv6 software VLAN routing feature which allows to cross over different VLANs and different IP addresses for the purpose of having a highly-secure, flexible management and simpler networking application.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRobust Layer 2 Features\u003c\/b\u003e\u003cbr\u003eThe IGS-5225-4P2S can be programmed for advanced switch management functions such as dynamic port link aggregation, Q-in-Q VLAN, private VLAN, Rapid Spanning Tree Protocol, Layer 2 to Layer 4 QoS, bandwidth control and IGMP snooping. The IGS-5225-4P2S provides 802.1Q tagged VLAN, and the VLAN groups allowed will be maximally up to 255. Via aggregation of supporting ports, the IGS-5225-4P2S allows the operation of a high-speed trunk combining multiple ports. It enables a maximum of up to 2 trunk groups with 2 ports per trunk group, and supports fail-over as well.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eEfficient Management\u003c\/b\u003e\u003cbr\u003eFor efficient management, the IGS-5225-4P2S is equipped with console, Web and SNMP management interfaces. With the built-in Web-based management interface, the IGS-5225-4P2S offers an easy-to-use, platform-independent management and configuration facility. For text-based management, the IGS-5225-4P2S can be accessed via Telnet and the console port. Moreover, it also offers secure remote management via any standard-based management software by supporting SNMPv3 connection which encrypts the packet content at each session.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePowerful Security\u003c\/b\u003e\u003cbr\u003eThe IGS-5225-4P2S offers comprehensive Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1x Port-based and MAC-based user and device authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/b\u003e\u003cbr\u003eWith the supported Modbus TCP\/IP protocol, the IGS-5225-4P2S can easily integrate with SCADA systems, HMI systems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s operating information, port information and communication status, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003cbr\u003e\u003cbr\u003e\u003cb\u003e1588 Time Protocol for Industrial Computing Networks\u003c\/b\u003e\u003cbr\u003eThe IGS-5225-4P2S is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFlexibility and Extension Solution\u003c\/b\u003e\u003cbr\u003eThe additional four mini-GBIC slots built in the IGS-5225-4P2S support dual speed, 100BASE-FX and 1000BASE-SX\/LX SFP (Small Form-factor Pluggable) fiber-optic modules, meaning the administrator now can flexibly choose the suitable SFP transceiver according to not only the transmission distance but also the transmission speed required. The distance can be extended from 550 meters (multi-mode fiber) to 10\/50\/70\/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eIntelligent SFP Diagnosis Mechanism\u003c\/b\u003e\u003cbr\u003eThe IGS-5225-4P2S supports SFP-DDM (Digital Diagnostic Monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eIndustrial Area Department\/Workgroup PoE Switch\u003c\/b\u003e\u003cbr\u003eProviding up to 4 PoE+, in-line power interfaces, the IGS-5225-4P2S can easily build a power centrally controlled for IP phone system, IP camera system, or wireless AP group for Industrial network. For instance, 4 PoE IP cameras or wireless access points can be easily installed around the corner in the industrial environment for surveillance demands or for a wireless roaming network. Without the power-socket limitation, the IGS-5225-4P2S makes the installation of IP cameras or wireless AP easier and more efficient.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-attributes\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eManagement features\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb-based management\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality of Service (QoS) support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch layer\u003c\/td\u003e\n\u003ctd\u003eL2+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch type\u003c\/td\u003e\n\u003ctd\u003eManaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003eTerminal block (3-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP module slots quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports type\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports quantity\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eNetwork\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of VLANs\u003c\/td\u003e\n\u003ctd\u003e4094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtual LAN features\u003c\/td\u003e\n\u003ctd\u003eMAC address-based VLAN, Multicast VLAN, Private VLAN, Protocol-based VLAN, Tagged VLAN, Voice VLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow control support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto MDI\/MDI-X\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcast storm control\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-negotiation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink aggregation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting entries\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalf duplex\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull duplex\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort mirroring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10G support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworking standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1ab, IEEE 802.1ad, IEEE 802.1ag, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3af, IEEE 802.3ah, IEEE 802.3at, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eData transmission\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket buffer memory\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames\u003c\/td\u003e\n\u003ctd\u003e9000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of static routes\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic route\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStore-and-forward\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput\u003c\/td\u003e\n\u003ctd\u003e8.928 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd\u003e12 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC address table\u003c\/td\u003e\n\u003ctd\u003e8000 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eSecurity\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic port security\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBPDU filtering\/protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSH\/SSL support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity algorithms\u003c\/td\u003e\n\u003ctd\u003eSNMP, SNMPv3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQueue scheduling algorithms\u003c\/td\u003e\n\u003ctd\u003ePriority queuing (PQ), Weighted Round Robin (WRR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGMP snooping\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Control List (ACL)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eMulticast features\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eMulticast support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eProtocols\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eGARP VLAN Registration Protocol (GVRP)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, CEIEC60068-2-32 (free fall)IEC60068-2-27 (shock)IEC60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall mountable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Protection (IP) code\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eActivity, Fault, Link, PoE, Power, Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset button\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (max)\u003c\/td\u003e\n\u003ctd\u003e151.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input voltage\u003c\/td\u003e\n\u003ctd\u003e48 - 56 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePower over Ethernet (PoE)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power over Ethernet (PoE) budget\u003c\/td\u003e\n\u003ctd\u003e144 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet (PoE) power per port\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet plus (PoE+) ports quantity\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e520.82 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e610 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e87.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eLogistics data\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85176990\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv id=\"icepim-pdf-urls\"\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.iceshop.nl\/objects\/mmo_65506767_1555675365_8258_14772.pdf\" target=\"_blank\"\u003emanual pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.iceshop.nl\/objects\/mmo_65506767_1555675400_3139_12594.pdf\" target=\"_blank\"\u003eleaflet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":55142009897345,"sku":"IGS-5225-4P2S","price":253.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/7725\/7955\/files\/22bccc9f32546daf93cbdbc092b413cd.jpg?v=1767621666","url":"https:\/\/eurobusinessproducts.co.uk\/products\/planet-igs-5225-4p2s-network-switch-managed-l2-gigabit-ethernet-101001000-power-over-ethernet-poe-blue","provider":"EuroBusiness Products UK","version":"1.0","type":"link"}